ED18 - Early Detection Analyzer

Troubleshooting Test Problems

DISPLAY
If the display does not turn on:
  1. Check the connection to the battery.
  2. Fully charge the battery and retest. The battery may be too weak to power the analyzer (below 1.0 volts).
  3. Replace the ED-18s internal batteries, which may need to be replaced. See Replacing the AA Batteries.
If the display flickers or is dim:
  1. The ED-18 housing is loose or missing screws.
  2. The contrast may need to be adjusted in the Setup menu. Highlight the Display icon and press "Enter." Use the arrow keys to scroll the contrast value to 95%.
  3. The ED-18 analyzer's internal batteries may need to be replaced. See Replacing AA Batteries.

TEST MESSAGES

System Noise / Check Loads: The analyzer has detected computer or ignition noise and will attempt to retest. Make sure all vehicle loads are off and the ignition is in the off position. The analyzer will automatically retest when it no longer detects system noise.

  1. You may be testing too close to a noise source, e.g., a charger or other high-current device. If so, move away and retest.
  2. If no noise source is identified, fully charge the battery and retest.
  3. Disconnect the battery cables and retest.
Unstable Battery: A battery that is very weak or that has just been charged may retain excess electrical activity, which the analyzer has detected and adversely affects the test results. A fully charged battery should stabilize quickly, after which the analyzer will automatically retest. Weak batteries should be charged and retested.
 
Home | Benefits | Success Stories | Features | Operation | FAQs | Contact Us | Interstate Dealers.com
© Interstate Battery System of America, Inc.